The settings panel of the Program object is shown in the figure.
Table describes the setting parameters corresponding to the elements of the settings panel of the Program object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* field | Automatically | Displays the identification number of the Program object in the video surveillance system |
Digits, letters, periods, hyphen, dash, and underscore |
NA | A line containing digits, letters, periods, hyphen, dash, and underscores. Depends on the number of the Program objects in the |
video surveillance system with distributed architecture | ||
2 | The Name* field | Enter the value |
in the field | Sets the name of the Program object | Latin alphabet, Cyrillic, digits and service characters | Program | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable checkbox | Set the checkbox |
Disables the Program object | Boolean type | Clear | Set—the Program object is disabled and isn't used Clear—the Program object is enabled and used |
4 | The Time schedule | Select the value from the list | Sets the time period during which the given program operates |
Name of the |
time schedule registered in the system | Never |
|
|
|
|
| ||||||
| The Computers group | ||||||
5 | The Select an element | |||||
checkbox | Set the checkbox | Sets the computer on which the given program |
is executed | Boolean type | Clear | Set—the program |
is executed on the specified computer Clear—the program |
isn't executed on the specified computer | |||
6 | The Computer field | Automatically | Sets the |
computer in the local network | Computer |
names in the local network | Computer name in the local network | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 | |
7 | The Name field | Automatically | Sets the name of the computer |
Names of the Computer object registered in the system | Name of the Computer object registered in the system | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 |
| Out of the group | ||||||
8 | ||||||
The Filter field | Enter the value in the field | Sets to pre-filter events processed by the program | Latin alphabet, Cyrillic, digits and service characters | NA | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited. The filter format is TYPE|ID|EVENT divided by semicolon. For example, the CAM||MD_STOP;CAM||MD_START format filters Alarm and Alarm end events from all Camera objects |
9 | The Text editor field | Enter the value |
in the field |
Enters the text of the executed program |
Latin alphabet, Cyrillic, digits and service characters |
NA | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. |
Number of |
characters—unlimited |
* Name of the element isn't displayed in on the settings panel of the given this object.