You can select and configure cameras for displaying in the Monitor interface window  window in two ways:

...

  1. Separately. The settings panel of the Monitor object is used.
  2. As a package. The
  3. In bulk. The Add/Edit Camera Objects
  4. dialog box is used.

...

titleNote
  1. window is used (the Range button), see Selecting and configuring video cameras

...

  1. in bulk.

To select video cameras individually on the settings panel of the Monitor object, do the following:

  1. Go to the List of cameras tab.
  2. To select all cameras registered in the system, click the All button
  3. (1)
  4. .
    Image Modified
  5. To add a separate camera, configure the following settings in the table
  6. (2)
  7. :
    1. From the drop-down list in the Number column, select the number of the
  8. required
    1. camera.
  9. As
    1.  As a result, the name of the selected camera will be automatically displayed in the Camera column.
    2. If multistream mode is enabled for the camera, in the Video stream drop-down list, select the number of the video stream that you want to display on the Monitor

  10. (4)
    1. . If no stream is selected, the default stream is used.

      Info
      titleNote

      Configuration of the Server video streams is described in

  11. Configuration of
    1. Configuring the multistream video. The selected video stream is requested when receiving a video signal both from the Server and via the Videogate.

    2. By default, the Monitor receives a video stream through the Server. If it is necessary to get the video stream directly from the camera, not through the Server,
  12. but directly
    1. from
  13. the camera, in
    1. the Connection drop-down list, select Direct.
    2. If a video signal needs to be decimated for its transmission to the Client Monitor, select the required frame rate of the video signal from the drop-down list in the fps column. 

      Note
      titleAttention!
  14. It is strongly not recommended to use
    1. We strongly discourage you from setting additional decimation and/or compression

  15. of the
    1. for video signals displayed on the Server Monitor, as

  16. it will lead to the additional spending
    1. this results in unnecessary consumption of the Server resources

  17. and deterioration of titleNote
    1. while the video image quality deteriorates.

  18. Info
    1. Features of fps selection:

      1. The selected FPS value
  19. should
      1. must be less than the frame rate of the video digitising by a video capture card. Otherwise, the frame rate of the video signal will be the same as the FPS of digitising.
  20. InfotitleNote
      1. For the correct decimation of a video stream compressed using the H.264 or MPEG4 codecs, the FPS value
  21. should
      1. must be equal to the frame rate of the key frames specified in the device settings (IP
  22. -
      1. camera)
  23. or
      1. or Axxon PSIM settings (
  24. see 
      1. see Configuring video compression).
  25. info
  26. title Note
      1. Four streams for a chip are processed on SC300Q16 (FX4) video capture card. If the chip processes a stream without a signal (blue screen), then the total FPS is 10 (
  27. 4 x 2,
      1. 4x2.5 FPS) for one chip.
    1. From the Hardware decoding drop-down list, select default CPU decoder (blank value), Nvidia decoder, or Intel Quick Sync. Selecting a hardware decoder increases the load on the corresponding CPU. 
    2. If video signal compression level needs to be changed for transmission to the Client Monitor, select the required level of video signal compression from the drop-down list in

  28. the
    1. the Compression column. The compression level of the video signal increases from 0 (no compression) to 5 (maximum compression).

      Info
      titleNote

      If you change the compression level

  29. is set
    1. for the Client, the video signal on the Server

  30. needs to
    1. will be pre-decompressed, which will result in a great load increase on the CPU of the Server.

    2. To change the algorithm of the video signal compression for transmission to the Client Monitor, select the required algorithm of compression from the Compressor drop-down list. If the compressor is selected, the value in the Compression list is

  31. should
    1. must be selected as well.

      Info
      titleNote

      Recompression of the video signal is performed on the Videogate side.

    2. If the Monitor
  32. should
    1. must receive live and archive video from the selected camera via the Videogate object, select the name of this object from the drop-down list in the Gate column.
    2. If a video archive from the selected camera

  33. should
    1. must be transmitted to the Monitor from the Backup archive object, select the name of this object from the drop-down list in the Backup archive column.

      Info
      titleNote
      In case the access to the Backup archive is performed through the Videogate, the specified value
  34. should
    1. must coincide with the selected value for this video camera
  35. while
    1. when configuring the Videogate
  36. objectsee
    1. object—see Selecting and configuring the cameras for the Videogate module.
    2. If the selected video camera is used for video archive viewing from the edge storage, select the required Edge storage object from the Edge storage drop-down list.
    3. If the tansmission from the Backup archive object is performed via the Videogate object, select the name of this object from the drop-down list in the Videogate for Backup archive column.
    4. To enable smart search in the archive of the corresponding camera, select the VMDA metadata storage object corresponding to the VMDA tracks database intended to be used for smart search from the VMDA metadata storage drop-down list.
    5. If there is a fisheye or a panomorph lens on the camera (see Configuring fisheye cameras), in the Display type drop-down list, select the type of displaying video from the camera in the Surveillance window: virtual telemetry or panorama.

      Info
      titleNote

      Conversion is enabled in the Video surveillance monitor when zooming

  37. -
    1. in (see Mouse PTZ control) or in the function menu of the Surveillance window (

  38. see
    1. see Enabling fisheye).

  39. InfotitleNote
    1. This feature won't work if:

  40. for
  41. boxes

    1. If it is necessary to start macros from the camera function menu in the Surveillance window, select the corresponding Macro objects from the Macro 1 and Macro 2 lists. See also Creating and using macros.
    2. The Guid column will automatically display the unique identifier of the selected camera. This value cannot be changed, it depends on the camera number.
    3. Repeat steps a-n for all required
  42. video cameras.
    1. cameras. To add new cameras to the table use the down arrow button ↓ on the keyboard. To delete a row, use the Ctrl+Del key combination.
  43. To save all changes, click the Apply button
  44. (3)
  45. .

Video cameras on the settings panel of the Monitor object are now selected.