Registry keys reference guide

All the events events that Auto PSIM receives from the LPR channel, are stored in the SQL database. Eventually it , the SQL database reaches a large size, which leads to the Server CPU load increase. To limit the SQL database size, you can specify the retention period of the database records.

...

  1. Go to the settings panel of the LPR channel object, corresponding to the activated module (see Activating the software module used for identifying the plates).
  2. Go to the Saving settings tab (1).
  3. In the Archive size, days field (2), specify the number of days that records are stored in the database. The default value is 30. The value range is 0-5000.
  4. Click the Apply button (3).

The database records retention period is configured.