Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Select the created NGP manager object in the hardware tree.
  2. Enter the information of the Axxon One instance you are connecting to:
    FieldDescriptionDefault value
    AddressIP address127.0.0.1
    PortPort for communication with the client (NativeBL port)20109
    Base portPort for operations within a domain20111
    Web portWeb server port (HTTP port for failover server)80
    LoginAxxon One usernameroot
    PasswordAxxon One passwordroot
    If you use a cloud connection for authorization in Axxon One, set the Cloud checkbox.
    Info
    titleNote

    The connection ports depend on the type of Axxon One installation (failover or not) and its settings. For more information, see the Axxon One documentation:

    Ports used by Axxon One

    Configuring the Server ports

    Ports used by the failover system

    Changing ports in the nodes of the failover system

  3. Click the Refresh button to synchronize with Axxon One. This button initiates reading and updating of the Axxon One configuration to retrieve information and send it to Axxon PSIM:
    Note
    titleAttention!

    Specifics of synchronization with Axxon One using the Refresh button:

    • After you click the button, you must wait for the process to complete without taking any further actions. This ensures that the states of Axxon One objects are correctly transferred.
    • If the configuration of a running Axxon One server was previously retrieved and during the next synchronization the server status is "off," the hardware state in Axxon PSIM remains unchanged. This is done to prevent accidental configuration clearing, for example, if the Axxon One server is rebooting during synchronization.
    • If you enter data of a new Axxon One domain for synchronization, the data of the previously synchronized domain are deleted. If synchronization is done with a server from the same domain, the data remain.
    • The hardware list, which was already retrieved, is synchronized between Axxon PSIM and Axxon One on the fly. However, to obtain information about new hardware or changes in the Axxon One configuration, you must click the Refresh button again.
    • If you delete devices and macros received from Axxon One (and they remain in Axxon One) in Axxon PSIM, they are recreated in Axxon PSIM during the next synchronization.
    • Hardware objects retrieved from Axxon One are created in Axxon PSIM without settings panels, as they can only be configured in Axxon One.
    • Macros are created without predefined conditions, but you can configure them if needed. For more information, see Working with macros and events received from Axxon One.

    The result of the synchronization is displayed in the information fields Last successful synchronization and Last synchronization state. If the synchronization is successful, the hardware received from Axxon One appears in the hardware list, and the received macros appear in the Macros list on the Programming tab:

  4. If you connect to the Axxon One failover server, set the Failover server checkbox and select from the drop-down list on the right, the server whose cameras are displayed in the NGP monitor window. If you connect to a regular server, not the Axxon One failover server, you can skip this step.In
  5. If you have the Axxon One client preinstalled, then when you create an integration object, the Path field
  6. , specify
  7. will automatically contain the path to the
  8. previously installed
  9. Axxon One
  10. client AxxonOne.exe (see 
  11. root folder (see Preconfiguration of Axxon One)
  12. that will be
  13. . This path is used to launch the NGP monitor interface object. If
  14. the path is known, it is set automatically. Otherwise
  15. you don't have Axxon One installed, the field remains empty. In this case,
  16. and you must enter the path to the file manually
  17. you need to install Axxon One and enter manually either the path to the Axxon One root folder or the gui_safe_mode.exe path if you are using an older version of OpenGL (see Create and configure the NGP monitor object).
    Note
    titleAttention!

    Note that this path must be the same on all computers where you want to run the Axxon One client AxxonOne.exe. This means that the Axxon One client must be pre-installed in the same folder on all computers.

  18. Click the Apply button.

Integration with Axxon One is complete.

...