Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


This section provides step-by-step instruction for installing the Axxon PSIM software to the Monitoring Workplace.

Note

Note the following features during the installation of the Axxon PSIM software:

  • Install the Axxon PSIM software on a clean Windows OS (see the Operating system requirements section).
  • To install the Axxon PSIM software, administrator rights are required.
  • Install the Axxon PSIM software in the directory, which is specified by default in the corresponding dialog window of the installation program (that is, C:\Program Files\PSIM). We highly don't recommend changing the name of the logical disk and the directory of the installation program.
  • Versions of the Axxon PSIM software installed in the configuration of the Client and Server/Administrator's workstation must be the same. Otherwise, we don't guarantee their proper cooperation.

To install the Axxon PSIMMonitoring Workplace software, do the following:

  1. Unpack the archive downloaded from the official website of the company, in accordance with the manual in the Getting ready for Axxon PSIM installation section. The destination folder displays the content of the distribution kit.
  2. Run the setup.exe executable file designed to start the Axxon PSIM installation program.
    As a result, the dialog window for selecting the language of the installation program is displayed.

    Attention!

    When you install Axxon PSIM on the OS Windows 8 and the OS Windows Server 2012, you must install Microsoft.Net Framework 8.0 or later. Otherwise, it is installed along with Axxon PSIM

  3. Select the language of the installation program from the list and click the Install button.

    As a result, the dialog window for selecting the type of installation is displayed.
  4. Select the Workplace for monitoring installation type.
  5. Set the Enable full installation log checkbox (increases the time of the software installation) if you want to write all software installation events to the log file.

    Note

    When you install the software, the event logging is performed in the PSIMSetup.log log file. To collect log files, we recommend using the Support.exe utility (see The utility for collecting configuration data on servers and RWS for the Technical Support section).
  6. Click the Next button.
    The dialog window for selecting the components for installation is displayed.
  7. Set the checkboxes next to the components that you want to install (you can expand the lists by clicking ). Consider the following peculiarities when you select the components:
    1. We recommend installing all provided components—the Axxon PSIM installer sets checkboxes next to everything required for proper operation by default.
    2. To operate in Axxon PSIM, you must install Microsoft.Net Framework 4.0 or later. Usually it is bundled with Windows OS and doesn't require separate installation. If you don't have it, then .Net 4.6 is offered for installation at Prerequisites—make sure to set the checkbox. For more information about Microsoft.Net Framework, see the official documentation at https://learn.microsoft.com/en-us/dotnet/framework/.

      Note

      If this method of language installation isn't suitable, later you can install each language separately (see Installing the language). After the installation, use the tweaki.exe utility to switch languages (see Switching languages in the Axxon PSIM Software System).

  8. Click the Install button.
    After that, the automatic installation of the selected components is performed.

    Attention!

    The installation of the required prerequisites can take a lot of time (more than 10 minutes).

    After you complete it, the Axxon PSIM welcome dialog window for the installation is displayed.

  9. Click the Next button.
    The dialog window with the license agreement is displayed.
  10. Read the license agreement and accept its terms by setting the switch into the I accept the terms of the License agreement position, otherwise the Axxon PSIM installation is stopped.
  11. Click the Next button.
    The dialog window for selecting the installation mode is displayed.
  12. Select the installation mode.
  13. Click the Next button.

    When you select the Custom installation mode, the dialog window for selecting the installation path is displayed. When you select the Standard installation mode, this step is omitted.

    The advanced settings dialog window is displayed.

  14. If necessary, you can create the Axxon PSIM desktop shortcut and set the corresponding checkbox.
  15. If necessary, you can create the Axxon PSIM desktop icon in the quick launch toolbar and set the corresponding checkbox.
  16. Click the Next button.
    The ready to install dialog window is displayed.

    Note

    To change the setting, click the Back button.
  17. Click the Install button.
    Then the dialog window of the Axxon PSIM installation process is displayed.
  18. The dialog window for completing the installation of Axxon PSIM is displayed.
  19. Set the Explore new ways for building your solutions checkbox to view the document containing the information about new features of the installed Axxon PSIM version.
  20. Click the Finish button.

    Note

    After that, the Driver Pack add-on installation starts.

    Then the installation wizard dialog window is displayed, containing the information about the status (installed or not) of the Axxon PSIM components.
  21. Click the Finish button.

Installing the Axxon PSIM software with the Monitoring Workplace installation type is complete. 