Previous page Next page

On the page:

 


General information

Fill out the following fields to prepare your infrastructure for Axxon Datacenter deployment. Please provide the requested information and confirm the necessary settings.

Remote access

Select the preferred option of remote access for AxxonSoft engineers (from best to least convenient):

  • Direct access via SSH.
  • SSH access via VPN.
  • RDP connection to a dedicated host and SSH to the servers.
  • VPN to RDP host and SSH to servers.

Внимание!

TeamViewer, AnyDesk, and other similar remote access options aren't supported.

Provide details on the selected option (for example, IP addresses, ports, credentials):

________________________________________________________________________________________________________________________

Servers

Installation type of Axxon Datacenter

  • Cloud: All instances of Axxon Datacenter are located in the cloud.
  • Hybrid: All instances of Axxon Datacenter are installed both in the cloud and on-premises.

AxxonNet servers

Number of AxxonNet servers:

  • 1 server
  • 3 servers (for a failover cluster)

Specify access parameters for each server (an external IP address is required during setup):

Server IP addressSSH portLoginPassword
AxxonNet 1




AxxonNet 2 (if applicable)



AxxonNet 3 (if applicable)



Axxon One servers

Number of Axxon One servers:

  • 1 server
  • 3 servers (for a failover cluster)

Specify access parameters and CPU model for each server:

ServerIP addressSSH portLoginPasswordCPU model
Axxon One 1




Axxon One 2 (if applicable)




Axxon One 3 (if applicable)




Storage

Type of storage for video archive

Attention!

NAS or object storage must be accessible from each Axxon One server as a shared partition.

Select the type of storage:

  • Network-attached storage (NAS)
  • Object storage (S3-compatible)

Storage parameters

If you select NAS:

  • Mount point: ________________________________
  • Access protocol: [________________________________] NFS, [________________________________] SMB/CIFS
  • Network path (UNC): ________________________________

If you select object storage:

  • Type of solution:
    • Amazon S3
    • Microsoft Azure Blob Storage
    • Wasabi Hot Cloud Storage
    • Huawei Cloud OBS
    • Seagate Lyve Cloud
    • MinIO (private deployment)
  • Endpoint: ________________________________
  • Bucket name: ________________________________
  • Access Key: ________________________________
  • Secret Key: ________________________________
  • Region (if necessary): ________________________________

Licensing

Select the option of using the license server:

  • AxxonSoft provides access to a corporate cloud license server. Access from Axxon One servers to the AxxonSoft server is required (ports 80 and 443 are open).
  • The license server is deployed on the customer's premises. Provide server details (if applicable):
    • IP address: ________________________________
    • SSH port: ____
    • Login: ________________
    • Password: ________________
    • USB hardware key: [_______________________________] installed

Domain settings

External IP address for the AxxonNet portal

This IP will host the AxxonNet web portal. IP address: ________________________________

Domain name for AxxonNet

  • AxxonSoft provides a name like <clientname>-demo.axxoncloud.com.
  • The customer provides a domain name. An A/CNAME DNS record must point to the external IP address specified in the External IP address for the AxxonNet portal section.
    Enter the domain name: ________________________

SSL certificate

  • AxxonSoft provides a Let's Encrypt certificate. Ports 80 and 443 must be open for the Let's Encrypt servers.
  • The customer provides an SSL certificate and private key. A standard certificate (for example, DigiCert Basic TLS/SSL) is sufficient. Attach files:
    • Certificate (in PEM format): ____________________
    • Private key: ____________________

Mail server

Select an option of setting up email notifications:

  • The customer's SMTP server. Specify the parameters:
    • IP address of the SMTP server: ________________________
    • Port: ____
    • Login: ________________
    • Password: ________________
    • Sender's address (email): ________________
    • Access from the AxxonNet server to the SMTP server: [________________] provided (no port restrictions).
  • Mailjet account (if SMTP server isn't available). The customer registers a Mailjet account, provides a login/password, and configures DNS:
    • Mailjet login: ________________
    • Mailjet password: ________________
    • SPF/DKIM/TXT records in the DNS zone: [________________] added (AxxonSoft can help with setting up, but it is necessary to have access to DNS).
  • For demo installations only—AxxonSoft provides a Mailjet account. Access from the AxxonNet server to the Mailjet servers via ports 25 and 587 is required.

System settings (required)

Confirm that the following requirements are met:

RequirementStatus (Yes/No)Comment

On all servers

Ubuntu LTS 20.04 or 22.04 OS is installed

All necessary Linux patches are installed

NTP server is configured
NTP server address: ________________________________
The required time zone is set

Network requirements

Ports 22, 80, 443 are open (incoming/outgoing)



Full internet access is allowed from all servers

Any traffic is allowed between all servers of the project (without firewall restrictions)

UFW is disabled (port configuration via iptables if necessary)

Access from Zabbix proxy hosts to port 10051 of the AxxonSoft external monitoring service is provided



Incoming traffic to port 10051 is allowed for Zabbix Proxy in the local network

Contact information of the person in charge

Contact information if any questions arise:

  • Company:  ________________________________
  • Full name: ________________________________________________________________
  • Job position: ________________________________
  • Email: ________________________________
  • Phone: ________________________________

Thank you for the provided information! After we receive the filled out checklist, AxxonSoft engineers will begin configuring the platform.

  • No labels