Universal reader can read both the card number and user data from the card.

You can work with a universal reader either via Perco reader or via Virtual reader.

Perco reader

  1. To work via Perco reader, select it from the reader drop-down list.

  2. From the COM-port drop-down list, select the COM port to work with the reader.
  3. The user data is read on the Read data tab.

    1. From the Block drop-down list, select the format of the protected block of a card memory: Digit or Hex.

    2. From the Key type drop-down list, select one of two types of the access key to the protected block of a card memory: A or B.

    3. In the Key field, specify a key that protects access to the protected block of a card memory.
    4. Click the Read data button. The process of reading the data of an access card starts.
  4. Card number is read on the Read UID tab.
    1. From the Format drop-down list, select a format of an access card: Digit, HEX, W24, W32.

    2. From the Reader version drop-down list, select which Perco reader will be used to read the number of an access card.

    3. From the Invert UID drop-down list, select Yes if you want to invert the number of an access card. By default, inversion is disabled.
    4. Click the Read UID button. The process of reading the number of an access card starts.

Working with Perco reader is complete.

Virtual reader

  1. To work via Virtual reader, select it from the reader drop-down list.

  2. The user data is read on the Read data tab.
    1. From the Block drop-down list, select the format of the protected block of a card memory: Digit or Hex.
    2. From the Key type drop-down list, select one of two types of the access key to the protected block of a card memory: A or B.
    3. In the Key field, specify a key that protects access to the protected block of a card memory.
    4. Click the Read data button. The process of reading the data of an access card starts.

  3. Card number is read on the Read UID tab.

    1. From the Format drop-down list, select a format of an access card: Digit, HEX, W24, W32.

    2. Click the Read UID button. The process of reading the number of an access card starts.

  4. The data of MyKad identification card is read on the Read MyKad data tab.

    1. Click the Read MyKad data button. The process of reading the data of MyKad identification card starts.

      Note

      MyKad card is used for identification in Malaysia. MyKad card can be read using a universal reader. You can enter a card number in the corresponding user fields in the Access Manager. You can also enter the following user data: name, surname, address, photo.


Working with a virtual reader is complete.