The video surveillance monitor for a web browser is used for remote video surveillance over the protected facilities using a web browser and TCP/IP communication environment. However, remote video surveillance through a web browser does not require Axxon PSIM to be installed.
Attention!
The color of the video surveillance window outline and text of the camera name display the status of the surveillance camera corresponding to the given surveillance window.
Color of the surveillance window outline | Color of the camera number outline | Camera status |
|---|---|---|
Yellow | Yellow | The camera is armed, recording isn't performed |
Red | Red | An alarm event has been registered on the camera, recording on alarm is in progress, or recording initiated by the operator's command before the alarm continues |
Green | Red | The camera is disarmed, recording initiated by the operator's command is in progress or additional recording on alarm is in progress |
Yellow | Red | The camera is armed, recording initiated by the operator's command is in progress or additional recording on alarm is in progress |
Green | Green | The camera is disarmed, recording isn't performed |
Red | Yellow | An alarm event has been registered on the camera; however, recording on alarm isn't in progress |
Note
All indication patterns correspond only to the main detection areas, without additional areas. When you arm or disarm a camera within an additional detection area, the color of the surveillance window outline remains unchanged; however, in case of an alarm event in the additional area, the color of the surveillance window outline turns red. That is why indication of arming and disarming of the camera in additional areas isn't performed.