Attention!

For detailed information on how to configure DEA FUSION P2P controller, please refer to the FUSION P2P Service Software Manual.

In order to configure minimum required settings which allow communication between DEA FUSION P2P controller panel and Axxon One, you may do the following:

  1. Install Virtual comport driver, which is used to connect the DEA FUSION P2P controller to the computer via USB port.
  2. Connect DEA FUSION P2P controller to the computer via USB port.
  3. Open FusionLightService.exe.
    Login window will appear. 


    ParameterDefault value
    Usernameinstallatore
    Passworddea
  4. Go to Options.
  5. Go to Serial port. Select the device which is to be configured from the list, and then press OK.
  6. Go to Board connection. For the Type of connection, select USB Port, and then press OK.
  7. Fill in the password and press OK.

    Controller configuration interface will be displayed.
  8. Go to Configuration.
  9. In the Clients DeaMap.dll / SC-DN-ETHSRV parameters tab, configure the following settings:

    1. In the Name field, specify name for the account.
    2. In the Address field, specify the IP address of the Axxon One server on which the DEA Security Fusion P2P integration module will run.
    3. In the Password field, specify a secure password.
    4. In the Port field, specify the port which is to be used to establish the connection for the user.
    5. For the Receives, Modify and TCP fields, set the value to 1.

      Note

      The values of the NamePassword and Port parameters will be necessary to configure Dea Security Root object of the DEA Security Fusion P2P integration module in Axxon One.

  10. Go to Network tab and configure network settings.
    1. In the Local parameter group, configure network settings of the DEA FUSION P2P controller.

      Note

      It is recommended to configure static IP address.

    2. In the DeaMap.dll board parameters group, set up an unique Name, Port, and Password.
    3. Press the OK button.

      Note

      The values of Ip Add, Name, Port and Password parameters will be necessary to configure Fusion P2P Controller object of the DEA Security Fusion P2P integration module in Axxon One

Preliminary configuration of the DEA FUSION P2P controller is complete.