To configure the Sensor object corresponding to the operator call button on the SIP-device, do the following:

  1. On the Hardware tab select the Video Capture Device object corresponding to the SIP-device.
  2. Click the right mouse button on the selected Video Capture Device object and choose the Create object -> Sensor item from the context menu.
  3. In the opened box enter the number and name of the Sensor object and then click Apply.

  4. As a result the settings panel of Sensor object will display.

  5. Set the Alarm at switch on checkbox (1).

  6. To save changes click Apply button (2).

Configuring of the Sensor object corresponding to the operator call button on SIP-device is completed.

 The Sensor object of SIP-device is program generated and is not connected directly with relay outputs of Axis video server, call button and “call duplicate” of security intercom terminal card.