Intellect allows sending events from the system objects to the VideoGuard server (see http://videoguard.ae/). In this case, Intellect acts as a client of the VideoGuard system.
The integration with the VideoGuard system is configured as follows:
- Create the VideoGuard integration client object on the basis of the Computer object on the Hardware tab of the System Settings dialog box (1). If data from several Intellect servers in a distributed system are to be sent to VideoGuarg, then create and configure separate VideoGuard integration client objects under each server.

- In the Server address field, enter the connection address to the VideoGuard server (2).
- From the IP-interface drop-down list, select the network adapter which is used to connect this computer to the VideoGuard server (3).
- In the Device ID on the server field, enter the identifier which is assigned to Intellect on the VideoGuard server (4). There should be no more than 6 digits in this field.
- In the Ping sending period field, specify the Heart Beat messages sending frequency in seconds (5). The default value is 300 seconds.
- Configure the correspondence between the VideoGuard and Intellect events. By default, the correspondence table contains the mandatory events, and their correspondence with the Intellect objects events is configured. If necessary, you can change this correspondence and add additional events:
- From the Server event ID drop-down list, select the event identifier on the VideoGuard server (6). See the supported values in the table below.
- From the Computer drop-down list, select the name of the Computer object. The selected events of the objects, which are based on this Computer object, will be sent to the VideoGuard (7). If the value is not specified, the events are sent from the specified objects, regardless of which Computer object they are based on; in this case such events may not be processed correctly in VideoGuard.
- From the Type drop-down list, select the Intellect object type, the events from which should be sent to the VideoGuard server (8).
- From the Number drop-down list, select the Intellect object identifier, the events from which should be sent to the VideoGuard server (9). If the identifier is not specified, then events are sent from all objects of the selected type.
- After you select the object type and identifier, the Name field will be automatically filled with the name of the selected Intellect object (10).
- From the Event drop-down list, select the event which is coming from the Intellect object of the selected type and which corresponds to the VideoGuard server event with the specified identifier (11).
- Click Apply.
The integration with the VideoGuard system is configured.
Restart Intellect after connecting to the VideoGuard server to synchronize the time with the VideoGuard server. After Intellect restart, the time zone in Windows is synchronized with the specified VideoGuard server.
The event identifiers supported on the server:
| ID | Description | Corresponding Intellect event |
|---|
| 1 | No video signal | Camera: Connection lost |
| 2 | Video source connection | Camera: Connection |
| 3 | Disk overflow | - |
| 4 | Error writing to disk | Camera: File record error |
| 5 | Client connection | Computer: Connection |
| 6 | Client disconnection | Computer: Disconnection |
| 7 | Motion detection trigger | Camera: Alarm |
| 8 | Case opening (Shelter Alarm) | - |
| 9 | Start of recording to the archive | Camera: Harddisk rec |
| 10 | End of recording to the archive | Camera: Record on disk stopped |
| 11 | Change of recording to the archive schedule | - |
| 100 | Additional event | Used to send additional events to the VideoGuard server. In this case, the event source identifier is added to the event identifier. Example: 
The event with the "101" identifier will be sent to the VideoGuard server. |