The workability software control allows restarting a module or the Axxon PSIM core if there is no response from this module.
To configure the software control of workability, do the following:

Modules whose state is determined as In process are marked with the |
You can restart the system if there is no response from the module after the waiting interval. |
In case you don't want to restart the system when there is no response from the module, select the none value. |
The module switches to the Shutdown state if the number of performed restarts exceeds the maximum one during the current time period. |
The counter of the remaining restarts can reset in the following cases: 1. The counter is reset upon the new restart if the time period during which the maximum number of restarts can be performed expires and the number of performed restarts doesn't exceed the maximum one. 2. The module restarts and the counter is reset if the time period during which the maximum number of restarts can be performed expires and the maximum number of restarts is performed. |
Configuring the software control of workability is complete.