The Testing video capture cards section is designed to test the connection of the cameras to the video capture card.
| To use this functionality Intellect is to be logged off. Otherwise there is “Cards not found” message. |
The settings panel for the Testing video capture cards section is shown in the figure.

The parameters of the settings panel are described in the table.
No | Parameter name | Field type | Description | Representation | Default value | Value range | |
1 | The Board dropdown list | Dropdown list | Specifies the video capture card which camera connections are to be checked | List of video capture cards | - | Depends on the number of installed video capture cards
| |
2 | The Test button | Click the button | Starts the testing process of the video capture card. The Intellect system is to be closed at the time of testing. | - | - | - | |
The Channels state table | |||||||
3 | The Channel column | Automatically | Displays the channels numbers of the selected video capture card | - | - | From 1 to 16
| |
4 | The State column | Automatically | Displays the state of camera connections to the channels of the selected video capture cards |
|
| Attach – camera is attached Detach – camera is detached | |