In order to configure Vanderbilt SPC integration module, perform the following actions:
- Select the main Vanderbilt object.

- In the RCT id field, enter RCT id configured in the FlexC ATS settings of the Vanderbilt SPC panel.
- In the RCT IP field, enter IP address of the machine on which Vanderbilt module is added. It must be in the same network as Vanderbilt Panel.
- In the RCT port field, enter the port number configured in FlexC ATS settings of Vanderbilt SPC panel.
- Press the Apply button to save the settings.
- Press the
button, and from the drop-down list select Download configuration from device. - Press the Apply button.
As a result, all Vanderbilt SPC panels that are configured to connect with the machine with RTC IP address will be listed under the main Vanderbilt object.

| Because Vanderbilt SPC panel connects to the Axxon One server, the server’s firewall must allow traffic from the device with the RCT IP address and RCT port. |
In order to configure the Vanderbilt SPC panel, do the following:
- Go to Panel settings under the main Vanderbilt object.

- In the Use field, select Yes to enable communication with selected Vanderbilt SPC panel.
- Enter proper Username and Password.
- Press the Apply button to save the settings.
- Go back to the main Vanderbilt object.

- Press the
button, and from the drop-down list select Download configuration from device. - Press the Apply button.
As a result, integration module will download all Vanderbilt SPC panel objects, including Areas and Sensors.