In order to configure DEA Security Fusion P2P integration module, do the following:
- Select the main Dea Security Root object.

- In the Controllers to create field, enter the amount of Fusion P2P controller objects to be created.
- In the Dea Map name field, enter the Name parameter value from Clients DeaMap.dll / SC-DNETHSRV parameters tab in Fusion P2P configuration.
- In the Dea Map password field, enter the Password parameter value from Clients DeaMap.dll / SC-DNETHSRV parameters tab in Fusion P2P configuration.
- In the Dea Map port field, enter the Port parameter value from Clients DeaMap.dll / SC-DNETHSRV parameters tab in Fusion P2P configuration.
- In the State polling time [ms] field, enter the value for how often Axxon One will poll the Fusion P2P controller objects for updates.
- Click the Apply button to save the settings.
- Click the
button, and from the drop-down list select Download configuration from device. - Click the Apply button.
As the result, configured amount of Fusion P2P Controller objects will be created.

In order to configure Fusion P2P Controller object, do the following:
- In the Password field, enter the Password parameter value from DeaMap.dll board parameters group in Network tab in Fusion P2P configuration.

- In the Port field, enter the Port parameter value from DeaMap.dll board parameters group in Network tab in Fusion P2P configuration.
- In the Input to create field, enter the amount of Input objects to be created in Axxon One.
This setting does not control the amount of Line objects - the amount of configured Line objects will be automatically downloaded from the device. Every created Input object uses up an appropriate license. |
- In the IP address field, enter the Ip Add parameter value from Local group in Network tab in Fusion P2P configuration.
- In the Name field, enter the Name parameter value from DeaMap.dll board parameters group in Network tab in Fusion P2P configuration.
- Click the Apply button to save the settings.
- Go to DEA Security Root main object.
- Click the
button, and from the drop-down list select Download configuration from device. - Click the Apply button.
As the result, Line objects will appear on the device tree as configured on the device.
