The HTML Interface object is used to display the content of web pages and other files in the Axxon PSIM interface window. The settings panel of the HTML Interface object is shown in the figure.

The table describes the setting parameters of the HTML Interface object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the HTML Interface object in the system

Sequence of numbers

NA

From 1 to 2147483647.

Depends on the number of the HTML Interface objects in the system

2

Name*

Enter the value in the field

Sets the name of the HTML Interface object in the system

Latin, Cyrillic, numbers, and service characters

HTML Interface

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Disables the HTML Interface object in the system

Boolean type

Clear

Setthe HTML Interface object is disabled and isn't used

Clearthe HTML Interface object is enabled used

4

Display

Select the value from the list

Sets the Display parent object for the given HTML Interface object

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the system

The Coordinates group*

5

X

Enter the value in the field


Sets the X coordinate in the horizontal axis for the upper left corner of the HTML Interface window

% of the screen width

33

From 0 to M*100, where M is the number of the installed (computer) monitors

6

Y

Enter the value in the field


Sets the Y coordinate in the vertical axis for the upper left corner of the HTML Interface window

% of the screen height

33

From 0 to M*100, where M is the number of the installed (computer) monitors

7

W

Enter the value in the field

Sets the width of the HTML Interface window

% of the screen width

33

From 0 to M*100, where M is the number of the installed (computer) monitors

8

H

Enter the value in the field

Sets the height of the HTML Interface window

% of the screen width

33

From 0 to M*100, where M is the number of the installed (computer) monitors

9

 

The  button

Click the button

Opens the window for specifying the size and position of the HTML Interface using the mouse

NA

NA

NA

10

Monitor

Select the value from the list

Sets the number of the monitor that must display the interface object

Sequence of numbers

1

Depends on the number of the connected computer monitors

11

Allow moving

Set the checkbox

Allows moving the HTML Interface object using the mouse

Boolean type

Clear

Setit is possible to move the HTML Interface interface object using the mouse

Clearit isn't possible to move the HTML Interface interface object using the mouse

12Over all windows Set the checkboxAllows displaying the HTML Interface window on top of all windowsBoolean typeClear

Set—the HTML Interface window is displayed on top of all windows

Clearthe HTML Interface window is displayed in the standard mode

Out of the group

13

Homepage

Select the value from the list

Sets the homepage that must be displayed in the HTML Interface window

Name of the HTML page objects registered in the system

NA

Depends on the number of the HTML page objects in the system

The Objects table*
14Object typeSelect the value from the listSets the type of object, the state of which must be monitored using the HTML interfaceTypes of objects created in the systemNADepends on the number of objects created in the system
15IDSelect the value from the listSets the ID of the object, the state of which must be monitored using the HTML interfaceSequence of numbersNADepends on the number of objects created in the system
16Object nameAutomaticallyDisplays the name of the object, the state of which must be monitored using the HTML interfaceName of the object of the selected type with the specified ID NADepends on the number of objects created in the system

*Name of the element isn't displayed in the settings panel of the given object.