This section provides step-by-step instruction for installing the Axxon PSIM software with the Sever/Remore Administrator's workstation installation type.
Note the following features during the installation of the Axxon PSIM software:
|
To install the Axxon PSIM software, do the following:

Run the setup.exe executable file designed to start the Axxon PSIM installation program. As a result, the dialog window for selecting the language of the installation program is displayed.
When you install Axxon PSIM on the OS Windows 8 and the OS Windows Server 2012, you must install Microsoft.Net Framework 8.0 or later. Otherwise, it is installed along with Axxon PSIM. |


Set the Enable full installation log (increases product installation time) checkbox if you want to write all software installation events to the log file.
| When you install the software, the event logging is performed in the PSIMSetup.log log file. To collect log files, we recommend using the Support.exe utility (see The utility for collecting system data for the technical support service section). |

). Consider the following peculiarities when you select the components:If you perform the installation using the comprehensive installation package, including the vertical solutions modules, at this stage you can select the installed vertical solutions. You must select only those that you will actually use on this computer; there is no need to install everything. Vertical solutions are installed after you complete the Axxon PSIM Base installation. The installation process is described in the documentation for the corresponding vertical sollution (see the links at the bottom of the Documentation for Axxon PSIM page).
At this stage, you can refuse to install the MS SQL Express database server. In this case, at step 16, you must configure the connection to the remote database. After you complete the installation of Axxon PSIM, you can change the database connection parameters using the idb.exe utility—see Connecting the Axxon PSIM database. Note that Axxon PSIM operation is impossible without connection to any database source.
If this method of language installation isn't suitable, later you can install each language separately (see Installing the language). After the installation, use the tweaki.exe utility to switch languages (see Switching languages in the Axxon PSIM Software System). |
Click the Install button.
After that, the automatic installation of the selected components is performed except Microsoft SQL Server Express 2014 database server (required for operation with Axxon PSIM databases), that is installed manually (see Microsoft documentation).

The installation of the required prerequisites can take a lot of time (more than 10 minutes). |
After you complete it, the Axxon PSIM welcome dialog window for the installation is displayed.


Click the Next button.
When you select the Custom installation mode, the dialog window for selecting the installation path is displayed, and then the dialog window for selecting the Axxon PSIM components is displayed. When you select the Standard installation mode, these steps are omitted.

When you select a component, the description of the component is displayed in the installation window. |
The dialog window for specifying the path to the file with the license key is displayed.
| Leave the field blank if the key file is copied later. |
Click the Next button.
The dialog window for selecting the Axxon PSIM as a Service installation type is displayed.
When you install as a Service, the 64-bit version of Axxon PSIM isn't available. If you set this checkbox, then 32-bit modules are started after you install Axxon PSIM as a Service. |
Click the Next button.
The dialog window for selecting the MS SQL Server database server is displayed. Specify the authentication parameters during the connection.
If the computer Administrator performs the installation of Axxon PSIM, and Windows credentials are used for the SQL server authentication, the access to the database of any other user is impossible without the additional settings of the idb.exe utility and knowledge of the Administrator login and password. That is why we highly don't recommend using such an authentication method of the SQL server. |
Select the SQL-server using the Database Server drop-down list.
| If you want to use the SQL-server installed on this (local) computer, select the (local)\SQLEXPRESS item (set by default). |
You cannot connect different servers to one database. The server can use the remote database, but it results in high requirements for the network and other resources and can cause delays when you transmit events and states between cores that negatively affect the system performance. |
Set the authorization parameters that are used by Axxon PSIM during the connection to the SQL-server.
| If you install Axxon PSIM as a Service, select the SQL server authentication check, that is, set the switch to the Use the following username and password position and specify the login and password to authorize in the server database in the corresponding fields. If you want to connect to the database using Windows credentials, then for proper operation of Axxon PSIM under any other user, the user must have the corresponding SQL server permissions. |
Ways of authorization performed in the dialog window.
Ways of authorization | Windows user account | Use the following username and password (recommended) |
Usage | SQL server from the Axxon PSIM distributive (or from the distributive of the third-party vendor) and Axxon PSIM are installed on one computer | SQL Server from the Axxon PSIM distributive and Axxon PSIM are installed on the same computer. Meanwhile, the connection to the SQL server with the set username (login) and password can be performed from any remote computer that is in the same network domain of the TCP/IP network as the computer on which the SQL server is being installed |
SQL server and Axxon PSIM are installed on different computers that are connected through the TCP/IP network and are within the same network domain. Meanwhile, the user account that is currently authorized in Windows OS on the computer where Axxon PSIM is being installed must be created in Windows OS on the computer with the installed MS SQL Server | SQL server from the Axxon PSIM distributive and Axxon PSIM are installed on different computers that are connected through the TCP/IP network and are in the same network domain. Meanwhile, the set username (login) and password must correspond to the username (login) and password used to access the SQL server | |
The full-scale SQL server (additionally installed) and Axxon PSIM are installed on different computers, connected through the TCP/IP network and are within the same network domain. Meanwhile, the user account currently authorized in Windows OS on the computer where Axxon PSIM is being installed must be created on the remote SQL server | The full-scale SQL server (additionally installed) and Axxon PSIM are installed on the same or different computers that are connected through the TCP/IP network and are in the same network domain. Meanwhile, the set username (login) and password must correspond to the username (login) and password used to access the SQL server |
| For the SQL server installed from the Axxon PSIM distributive, the "sa" username and "PSIM_default_DB_4" password are used by default. When you install the Microsoft SQL Server Express 2014 server database, you can change the password to any other. |

button next to the Main database field.
button next to the Titles database field.Click the Next button.
| If the Rights are required to create or edit databases message appears during the system installation, you must stop the installation process and restart again. |
The advanced settings dialog window is displayed.
Click the Next button.
The ready to install dialog window is displayed.
| To change the setting, click the Back button. |
Click the Install button.
Then the dialog window of the Axxon PSIM installation process is displayed.

When you install Axxon PSIM on OS Windows 7 SP1 without the internet connection, the error during the driver installation for the FX4 card can occur. To eliminate this error, you must install the following missing Windows updates: |

Click the Finish button.
After that, the Driver Pack add-on installation starts. If the KB2999226 update is installed, but there is no software ability to identify it, run the Driver Pack installation from the command prompt with the SOFT_INSTALL = "yes" parameter.
|


Installing the Axxon PSIM software with the server installation type is complete.