The list of TCP ports used in Axxon PSIM is given in the table. You can change the ports using the ChangePort registry key.

MS SQL Server also uses the TCP port 1433 and the UDP port 1434 (by default) for database synchronization.

MS SQL can use dynamic ports to synchronize databases.

To specify which ports are used, go to the Start Microsoft SQL Server Express 2014  Configuration Tools  SQL Server Configuration Manager  SQL Server Network Configuration  Protocol for SQLEXPRESS  TCP/IP  IP Addresses menu and check which type and number of ports are specified in the IPAII parameter.

Configure the use of fixed ports according to the manual on the http://technet.microsoft.com/en-gb/library/ms177440.aspx Microsoft website if the use of dynamic ports is unacceptable. 

Ports 8085 and 8087 are used to connect clients to the Web Server 2.0 module.

This data is necessary for setting up the security system and firewall on the server. The Corresponding module to which connection is made parameter is set for client-server modules. 

Axxon PSIM base

Module name

Name of the corresponding object in Axxon PSIM

Connection port

Corresponding module to which connection is made

AnalogChart.run

Charts

22358 Remote

PSIM.exe

ARCHPANEL.RUN

Backup archive panel

22118 Remote

PSIM.exe

AUDIO.RUN

Microphone Audio card Sound notification

21008 Remote

PSIM.exe

AUDIO.RUN

Microphone

20903 Remote

VIDEO.RUN

AUDIO.RUN

Microphone

20904 Remote

VIDEO.RUN

AUDIO.RUNBackup audio archive20911 Local-
AUDIO.RUNAudio playback card20910 and 24008 Local-
BacNetInt.runBacNet22350 RemotePSIM.exe

CAM_TITLE.RUN

Captioner

21077 Remote

PSIM.exe

CloudAuth.run

CLOUD_AUTH

22442 Remote

PSIM.exe

CONFCHEKUTIL.RUN

Configuration check

22220 Remote

PSIM.exe

DIALOG.RUN

Operator query panel

21058 Remote

PSIM.exe

display_manager.run

Display Manager

22323 Remote

PSIM.exe

DRS.RUN

Data replication service

22175 Remote

PSIM.exe

EVENT_COUNTER.RUN

Event counter

22153 Remote

PSIM.exe

EVENT_VIEWER.RUN

Event viewer

21055 Remote

PSIM.exe

FIXMLServer.run

ISD integration server

22389 Remote

PSIM.exe

FIXMLServer.run

ISD integration server

20985 Remote

FIRSERVER.RUN

http_server.run

HTTP-server

22360 Remote

PSIM.exe

IIDK_TEST.EXE

IIDK interface

20900 Remote

VIDEO.RUN

IIDK_TEST.EXE

IIDK interface

21030 Remote

PSIM.exe

IIDK_TEST.EXE

IIDK interface

21111 Remote

PSIM.exe

INC_MANAGER.RUNIncident manager22401 RemotePSIM.exe
INC_MANAGER.RUNIncident manager22440 RemoteSystem
INC_SERVER.RUNIncident server22432 RemotePSIM.exe
INC_SERVER.RUNIncident server22439 LocalINC_MANAGER.RUN
IntegrationHTTPClient.runVideoGuard integration client22390 RemotePSIM.exe

JAVA.EXE

Web-server 2.0

22212 Remote

PSIM.exe

KEYB.RUN

Keyboard

21005 Remote

PSIM.exe

LDAPIMPORT.RUN

LDAP service

22252 Remote

PSIM.exe

LIVEPLAYER.RUN

Live sound switch

22199 Remote

PSIM.exe

Manitou.run

Manitou software

22302 Remote

PSIM.exe

MAP.RUN

Map

21051 Remote

PSIM.exe

MapServer

Map server 

22414 Remote

PSIM.exe

MC_CLIENT.RUN

Intercom Control Monitor

22179 Remote

PSIM.exe

MESSAGE.RUN

Alarm Message Window

21056 Remote

PSIM.exe

MMS.RUN

Mail Message Service

21031 Remote

PSIM.exe

monitor_an.run

NGP monitor

22395 Remote

PSIM.exe

OnvifServer.run

ONVIF-Server (NGP manager), ONVIF-Server

22250 Remote

PSIM.exe

OPCIE.RUN

HTML Interface

22141 Remote

PSIM.exe

OPERATORPROTOCOL.RUN

Operator protocol

22215 Remote

PSIM.exe

PLAYER.RUN

Audio player

20910 Remote

AUDIO.RUN

PLAYER.RUN

Audio player

21060 Remote

PSIM.exe

PSIM_HOST.EXE

Computer

21111 Remote

PSIM.exe

SipPanel.run

SIP panel

22331 Remote

PSIM.exe

SMS.RUN

Short Message Service

21035 Remote

PSIM.exe

StateStat.run

State statistics

22222 Remote

PSIM.exe

STREAMINGSERVER.RUN

RTSP Server (NGP manager), RTSP Server

22228 Remote

PSIM.exe

StreamTerminal.run

SIP terminal

22332 Remote

PSIM.exe

StreamTerminal.run

SIP terminal

22537 Local

-

Telegram.run

Telegram bot

22368 Remote

PSIM.exe

TELEMETRY.RUN

Telemetry Controller

21010 Remote

PSIM.exe

TELEMETRY_PANEL.RUN

Telemetry control panel

22101 Remote

PSIM.exe

TITLEVIEWER.RUN

Search by captions

20978 Remote

CAM_TITLE.run

TITLEVIEWER.RUN

Search by captions

22112 Remote

PSIM.exe

Video_ngp.run

NGP manager 

22420 Remote

PSIM.exe

Video_ngp.run

NGP manager 

20500 Local

-

Video_ngp.run

NGP manager 

20109 Local

-

VideoPSIMClient.run

VideoPSIMClient

22451 Remote

PSIM.exe

VIDEO.RUNCAM_TITLE.run, Detector_Ext.run20900 Local-

VIDEO.RUN

Video Capture Device

21050 Remote

PSIM.exe

VIDEO.RUN

Video stream archiver

20901 Local

-

VIDEO.RUN

Video stream gate

20902 Local

-

VMDADB.RUN

VMDA metadata storage

22219 Remote

PSIM.exe

VMS.RUN

Voice Message Service

21032 Remote

PSIM.exe

VNS.RUN

Voice notification service

21004 Remote

PSIM.exe

WEBSERVER.RUN

Web-server

21034 Remote

PSIM.exe

WINDOW.RUN

External window

21053 Remote

PSIM.exe

YITUClient.run

YITU Client

22452 RemotePSIM.exe


Monitoring PSIM

Module name

Name of the corresponding object in Axxon PSIM

Connection port

Corresponding module to which connection is made

forward.run

Data gateway

22327

PSIM.exe

CentralNetServer.exe

CSC

7755

VIDEOSRV.EXE

VIDEOSRV.EXE

IIDK interface

21030

PSIM.exe

VIDEOSRV.EXE

VideoServer

20900

VIDEO.RUN

VIDEOSRV_C.RUNAgent of Control22001-

VIDEOSRV_E.RUN

Search in archive

22003

PSIM.exe

VIDEOSRV_M.RUN

Monitoring

22222

PSIM.exe

VIDEOSRV_R.RUN

Monitoring reports

22223

PSIM.exe

VIDEOSRV_S.RUNServer of Control22002-
VIDEOSRV.EXEServer of Control7777VIDEOSRV.EXE

STATEUPS.EXE

(UPS operation)

-

8888

VIDEOSRV.EXE

BATDISCH.EXE

(UPS operation)

-

8888

VIDEOSRV.EXE

POWEROFF.EXE

(UPS operation)

-

8888

VIDEOSRV.EXE

POWERON.EXE

(UPS operation)

-

8888

VIDEOSRV.EXE

If CSC (Central Server of Control) is in use, then between the CSC communication server and the Server of Control, the 20 and 21 TCP ports are used to provide FTP operation. 

DetectorPack PSIM

Module name

Name of the corresponding object in Axxon PSIM

Connection port

Corresponding module to which connection is made

Detector_Ext.run

Fire detection

20993 Local

-

Detector_Ext.run

Fire detection

22221 Remote

PSIM.exe


ACFA PSIM subsystem

Module name

Name of the corresponding object in Axxon PSIM

Connection port

Corresponding module to which connection is made

axacfa.run

AxACFA

22428 Remote

PSIM.exe

axacfa.run

Honeywell 

22428 Remote

PSIM.exe

Esser.run

Esser

22396 Remote

PSIM.exe

glx2.run

Galaxy Dimension Panel

22300 Remote

PSIM.exe

suprema_cr.run

Suprema BioMini

22319 Remote

PSIM.exe

suprema_2.run

Suprema Biometrical ACS v2

22328 Remote

PSIM.exe

suprema_realscan.run

Suprema Realscan

22333 Remote

PSIM.exe

DataBridge.runData Bridge22293 RemotePSIM.exe
DataBridge.runData Bridge2555 RemoteAppHost.exe
vanderbilt_spc.runVanderbilt SPC22333 RemotePSIM.exe