You can start the UpdateDB Utility by right-clicking the Worktime tab in the Access Manager interface window.

As a result, the UpdateDB Utility window will open.

You can work with the UpdateDB Utility as follows:
To update the database, click the Update DB button (7). Both triggers and stored procedures, required for the correct operation of the subsystem, are updated. You need to do this once when connecting the Time and Attendance subsystem. The progress is displayed in the area (3). To cancel the action, click the
button (4).
If it is necessary to take into account the passes made before configuring the Time and Attendance subsystem, after starting the Time and Attendance subsystem in Axxon PSIM, re-account the database using the Re-account by Protocol (5) and Re-account by Region Pass (6) buttons. The progress is displayed in the area (3). To cancel the action, click the
button (4).
It is strongly not recommended to use the re-account buttons without recommendations of AxxonSoft technical support specialists! When you click the Re-account by Protocol button (5), the dbo.Region_Enter_Exit table is completely cleared and filled out again depending on the pass information currently contained in the dbo.protocol table. When you click the Re-account by Region Pass button (6), the dbo.Region_Enter_Exit table is completely cleared and filled out again depending on the pass information currently contained in the dbo.Region_pass table. Attention! Because of the different depth of the event archive of these tables, there is a risk of data loss when clearing the dbo.Region_Enter_Exit table. |


If the reaccounting is completed with an error, we recommend increasing the time for waiting for the system response by changing the value of the RecalcTimeoutInSec parameter in the account_manager_run.config file. The default value is 600 seconds. |
To close the UpdateDB Utility window, click the
button in the top right corner of the form.
Working with the UpdateDB Utility is complete.
By default, only the passes that were made after the installation and configuration of the Time and Attendance subsystem are taken into account. |