Contents

General information about working with the Satel INTEGRA integration module

The Satel INTEGRA integration module is managed through the Map, Equipment Board, and Event Board interface objects, along with Programming rules.

For the information on configuring these interface objects, see Configuring the interactive map, Configuring an Equipment Board and Configuring an Event Board.

For the information on working with these interface objects, see Working with the interactive map, Working with Equipment Board and Working with Event Boards.

For the information on configuring Programming rules, see Configuring macros and counters.

Managing the Satel INTEGRA objects

States

States available for various Satel INTEGRA objects are listed in the tables below:

  1. Group object:
    StateIconStateIcon

    Fire alarm in memory

    Disarm

    Exit time < 10s

    Arm

    Exit time > 10s

    Alarm

    Entry time

    1st code entered

    Input violated

    Disconnected

    Fire alarm

    Alarms verified

    Alarm in memory

    1st code entered (v.2)

    Warnings



  2. Panel object:
    StateIconStateIcon

    Fire alarm in memory

    Disarm

    Exit time < 10s

    Arm

    Exit time > 10s

    Alarm

    Entry time

    1st code entered

    Input violated

    Disconnected

    Fire alarm

    Alarms verified

    Alarm in memory

    1st code entered (v.2)

    Warnings



  3. Relay object:
    StateIcon

    Connection lost

    On

    Off

  4. LCD, Expander and Object (site) objects:
    StateLCDExpanderObject

    Connection lost

    Normal

  5. Door object:
    StateIcon
    Closed

    Connection lost

    Open

    Opened long

  6. Fire MCPPIRZoneMagnetic detectorPanic buttonPIR 360Seismic detectorAcoustic detector, and Smoke detector objects: 
    StateFire MCPPIRZoneMagnetic detectorPanic buttonPIR 360Seismic detectorAcoustic detectorSmoke detector
    Alarm

    Alarm in memory

    Arm

    Temporary locked (Bypass)

    Disarm

    Permanently locked (Isolated)

    Disconnected

    Masked

    Masked in memory

    Tamper

    Tamper alarm

    Tamper alarm in memory

    Violation too long

    No violation too long

    Violation

Commands

Commands accessible via Axxon One interface for various types of Satel INTEGRA objects are listed in the table below:

ObjectCommands
Panel Clear troubles memory
Partition

Arm
Disarm
Clear alarm
Force arming
Enter 1st code to arm
Enter 1st code to disarm
Cancel 1st code entered

Zone

Lock temporary
Unlock
Lock permanently

Output 

On
Off
Switch