Configuring general settings

To configure the general settings of Satel Ethma Input object, do the following:

  1. In the Notification type, select the type of displayed notifications in Axxon One: Active/Inactive, Normal/Failure, or Normal/Alarm.
  2. In Require the operator to clear the alarm from map field, select one of two possible states:
    1. No—Alarm message expires automatically upon object state change.
    2. Yes—The alarm message is displayed on the map until manually cleared by the operator.
  3. If the logic of the displayed icons needs to be reversed, set Reverse icon to Yes. Otherwise, set the value to No.
  4. In the Read as analog input field, select one of the two possible states:
    1. No—The input is treated as digital. Digital input settings apply.
    2. Yes—The input is treated as analog. Analog input settings apply.

      Note

      The values need to be kept consistent with the ones specified when configuring the Satel2 ETHM-A universal monitoring module via GX Soft tool (see Preparing the Satel2 ETHM-A universal monitoring module to work with Axxon One).

Configuring digital input

If the Read as analog input option is set to No, do the following:

  1. The Emulate extra events for digital input creates additional messages for low/high state. If the value is set to Yes, configure the following options:
    1. Define the message displayed when sensor state is high in Info for high state field.
    2. Define the message displayed when sensor state is low in Info for low state field.
  2. In Reverse events field, set the value to Yes if the logic of displayed events is to be reversed, or to No if the logic is to be kept as-is.

 Configuring digital input is complete.

Configuring analog input

If the Read as analog input option is set to Yes, do the following:

  1. The Emulate extra events for analog input creates additional state messages. If it is set to Yes, do the following:
    1. Define the message for alarm state in the Alarm state message field.
    2. Define the message for warning state in the Warning state message field.
    3. Define the message for normal state in the Normal state message field. 
  2. Define the buffer value in the Buffer field.
  3. Define the Low threshold value.
  4. Define the High threshold value.

Configuring analog input is complete.