In order to configure the DEA Security Fusion P2P integration module, do the following:

  1. Select the Dea Security Root parent object.
  2. In the Controllers to create field, enter the amount of the Fusion P2P controller objects to be created.
  3. In the Dea Map name field, enter the Name parameter value from the Clients DeaMap.dll / SC-DNETHSRV parameters tab in the Fusion P2P configuration.
  4. In the Dea Map password field, enter the Password parameter value from the Clients DeaMap.dll / SC-DNETHSRV parameters tab in the Fusion P2P configuration.
  5. In the Dea Map port field, enter the Port parameter value from the Clients DeaMap.dll / SC-DNETHSRV parameters tab in the Fusion P2P configuration.
  6. In the State polling time [ms] field, enter the value of how often Axxon One will poll the Fusion P2P controller objects for updates.
  7. Click the Apply button to save the settings.
  8. Click the button, and from the drop-down list, select Download configuration from device.
  9. Click the Apply button.

As the result, the configured amount of the Fusion P2P Controller objects will be created.

In order to configure the Fusion P2P Controller object, do the following:

  1. In the Password field, enter the Password parameter value from the DeaMap.dll board parameters group in the Network tab in the Fusion P2P configuration.
  2. In the Port field, enter the Port parameter value from the DeaMap.dll board parameters group in the Network tab in the Fusion P2P configuration.
  3. In the Input to create field, enter the amount of Input objects to be created in Axxon One.

    Note

    This setting does not control the amount of the Line objects. The amount of configured Line objects will be automatically downloaded from the device.

    Every created Input object uses up an appropriate license. 

  4. In the IP address field, enter the Ip Add parameter value from the Local group in the Network tab in the Fusion P2P configuration.
  5. In the Name field, enter the Name parameter value from the DeaMap.dll board parameters group in the Network tab in the Fusion P2P configuration.
  6. Click the Apply button to save the settings.
  7. Go to the DEA Security Root parent object.
  8. Click the button, and from the drop-down list, select Download configuration from device.
  9. Click the Apply button.

As the result, the Line objects appear on the hardware tree as configured on the device.

  • No labels