Go to documentation repository
Important!
Before configuring the joystick using the Windows OS tools, set the registry key DisableInternalJoystick = 0, see Registry keys reference guide.
If the joystick is connected to the Server and configured in Windows OS, then Axxon PSIM™ automatically activates the joystick telemetry control option. The option is valid for all PTZ devices connected to the Server and configured in Axxon PSIM™.
Generally the joystick configuration contains the following stages:
The following functions are available by default and do not require additional configuration:
Rotation of cameras equipped with PTZ devices is performed by inclining the joystick handle;
Note
Joystick threshold corresponds to the Joystick Threshold string parameter and is set int the HKLM\SOFTWARE\AxxonSoft\Axxon PSIM\Telemetry register of the Windows OS. By default Joystick Threshold=1, this parameter can possess values from 0 and more. The bigger the value, the less sensitive the joystick is, the best value is selected empirically.
Zooming option is performed by turning a joystick handle around its vertical axis.
The zooming option is available only for joysticks with Z axis, for example Axis 295. This axis is formed by joystick handle’s angles of rotation.
Z axis is enabled by default and corresponds to the value of Zenable=1 string parameter in the HKLM\SOFTWARE\AxxonSoft\Axxon PSIM\Telemetry register of the Windows OS.
Attention!
The coordinate of joystick Z axis is to be automatically zeroized after every zooming for proper telemetry control. Otherwise Z axis is to be disabled by setting the Zenable=0 parameter in the HKLM\SOFTWARE\AxxonSoft\Axxon PSIM\Telemetry section.
Note
Z axis is to be disabled when the Logitech USB joystick is used.