Go to documentation repository
This section outlines a provides step-by-step instruction on how to install INTELLECT™ software as a “Server”for installing the Axxon PSIM software with the Sever/Remore Administrator's workstation installation type.
| Info | ||
|---|---|---|
| ||
The following features are to be taken into account while installing INTELLECT™ Note the following features during the installation of the Axxon PSIM software:
|
To install INTELLECT™ the Axxon PSIM software, do the following:
Run the setup.exe executable file designed to start the INTELLECT™ software installation procedure.
the Axxon PSIM installation program. As a result, the dialog box of choosing language window for selecting the language of the installation program is displayed.
| Info | ||
|---|---|---|
| ||
The notification box is displayed if Microsoft.Net Framework 4.0 has not been installed. Click Yes for Microsoft.Net Framework 4.0 auto installation. |
| Note | ||
|---|---|---|
| ||
| When INTELLECT™ is installed on Windows 8 and Windows Server 2012 OS, the Microsoft.Net Framework 4.0 or later is to be pre-installed. If the Microsoft.Net Framework 4.0 or later has not been installed, then the warning is displayed. In this case stop installing INTELLECT™ and install the Microsoft.Net Framework 4.0 or later. You will find the instructions on how to install it at: http://msdn.microsoft.com/en-gb/library/hh506443.aspx |
When you install Axxon PSIM on the OS Windows 8 and the OS Windows Server 2012, you must install Microsoft.Net Framework 8.0 or later. Otherwise, it is installed along with Axxon PSIM. |
Set the Enable full
installation log(increases
product installation time) checkbox if you want to write all software installation events to the log file.
| Info | ||
|---|---|---|
|
| When you install the software, the event logging is performed in the PSIMSetup.log log file. To collect log |
| files, we recommend using the |
| Support.exe utility (see The utility for collecting configuration data on servers and RWS for the Technical Support section). |
| Info | ||
|---|---|---|
| ||
| All offered components are recommended to be installed. However, if installation is performed using the integrated software package (with vertical solutions modules), then there will be an option to select vertical solutions that are to be installed. Only those vertical solutions that will be in use are to be selected. There is no need to install all vertical solutions. Vertical solutions will be installed after installing Axxon Intellect Enterprise. Information on how to install vertical solutions can be found in the corresponding documentation. |
If you perform the installation using the comprehensive installation package, including the vertical solutions modules, at this stage you can select the installed vertical solutions. You must select only those that you will actually use on this computer; there is no need to install everything. Vertical solutions are installed after you complete the Axxon PSIM Base installation. The installation process is described in the documentation for the corresponding vertical sollution (see the links at the bottom of the Documentation for Axxon PSIM page).
At this stage, you can refuse to install the
| title | Note |
|---|
MS SQL Express database server. In this case
, at step 16, you must configure the connection to the remote database
. After you complete the installation of Axxon PSIM, you can change the database connection parameters
using the idb.exe utility
, see Connecting the Axxon PSIM database. Note that Axxon PSIM operation is impossible without connection to any database source.
If you are not installing from a disk, you will also be able to select the languages to be installed. To do this, download the language pack from AxxonSoft official website (https://www.axxonsoft.com/) before beginning the installation and put the archive's files into the languages folder in the installer's directory. As a result, the Selecting components for installation window will offer selection of languages to be installed.
| Info | ||
|---|---|---|
| ||
If this method of |
language installation isn't suitable, later you can install each language |
separately (see Installing the language). After the installation, use the |
tweaki.exe utility to switch languages (see Switching languages in the |
Click the Install button.
After that, the automatic installation of the selected components
are automatically installedis performed except Microsoft SQL Server Express
20142019 database server (
necessaryrequired for
work with INTELLECT™ databasesoperation with Axxon PSIM databases), that is installed manually (see Microsoft documentation).
| Info | ||
|---|---|---|
| ||
To ensure stable and proper operation of Axxon PSIM on the Windows 11 OS, we recommend using the Microsoft SQL Server 2019 Express database server or the newer version. |
| Note | ||
|---|---|---|
| ||
| Auto The installation of necessarythe required prerequisites maycan take a lot of time (more than 10 minutes). |
After this the Welcome to the Intellect Setup Wizard box you complete it, the Axxon PSIM welcome dialog window for the installation is displayed.
Click the Next button.
When you select the Custom installation mode is selected, the dialog box of choosing window for selecting the installation folder path is displayed, and then the Select components dialog box the dialog window for selecting the Axxon PSIM components is displayed. This step is omitted when the When you select the Standard installation mode is selected, these steps are omitted.
| Info | ||
|---|---|---|
| ||
The When you select a component, the description of the component is displayed in the installation box when this component is selectedwindow. |
The dialog box of window for specifying the path to the file with the license key file is displayed.
| Info | ||
|---|---|---|
| ||
| Keep Leave the field blank if the key file will be is copied later. |
Click the Next button.
The dialog box of installing Intellect window for selecting the Axxon PSIM as a service installation type is displayed.
| Info | ||
|---|---|---|
| ||
The When you install as a service, the 64-bit version of Intellect is not available when installed as a service. If this checkbox is set checked Axxon PSIM isn't available. If you set this checkbox, then 32-bit modules will be are started after installing Intellect you install Axxon PSIM as a service. |
Click the Next button.
The dialog box of window for selecting the MS SQL Server database server selection is displayed. Specify the authentication parameters to connect to itthe authentication parameters during the connection.
| Note | ||
|---|---|---|
| ||
Access of some user If the computer administrator performs the installation of Axxon PSIM,and Windows credentials are used for the SQL server authentication, the access to the database of any other user is impossible without the additional settings of the idb.exe utility and knowing knowledge of the administrator login and password of Administrator if installation of the Intellect software package is performed by Administrator and Windows account data are in use for SQL authentication. So it is highly recommended not to use such . That is why we highly don't recommend using such an authentication method of the SQL server. |
Select the SQL-server using the Database Server drop-down list.
| Info | ||
|---|---|---|
| ||
| If there is necessity you want to use the SQL-server installed on this (local) computer, select the “ (local)\SQLEXPRESS2014” SQLEXPRESS item (set by default) is to be selected. |
| Note | ||
|---|---|---|
| ||
You cannot connect different Serversservers to one database. ServerThe server can use the remote database, but requirements toit results in high requirements for the network and other resources become higerand thiscan cause delays while transmittingwhen you transmit events and states of coresbetween cores that negatively affect the system performance. |
Set the authorization parameters that will be used by INTELLECT™ while connecting are used by Axxon PSIM during the connection to the SQL-server.
| Info | ||
|---|---|---|
| ||
| If INTELLECT™ is installed you install Axxon PSIM as a service, select the SQL Server identity check, i.e. set the server authentication check, that is, set the switch to the Use the following username and password checkbox position and specify the username login and password to login authorize in the Server server database in the corresponding fields. If you want to connect to the database is to be connected via the Windows accountusing Windows credentials, then for proper operation of INTELLECT™ of Axxon PSIM under any other user, the user is to must have the corresponding SQL Server permissionsserver rights. |
Ways of authorization performed in the dialog boxwindow.
Ways of authorization | Windows user account | Use the following username and password (recommended) |
Usage | SQL Server server from Intellect the Axxon PSIM distributive (or from the distributive of the external third-party vendor) and Intellect is Axxon PSIM are installed on the same one computer | SQL SQL Server from Intellect the Axxon PSIM distributive and Intellect Axxon PSIM are installed on the same computer. Meanwhile, the connection to the SQL Server server with the set username (login) and password may can be performed from any remote computer that is in the same net network domain of the TCP/IP net with a computer, where SQL Server network as the computer on which the SQL server is being installed. |
SQL Server server and Intellect Axxon PSIM are installed on different computers that are connected through the TCP/IP net network and are in within the same net network domain. Meanwhile, the user account for the user that is currently authorized in Windows OS on the computer , where Intellect Axxon PSIM is being installed is to must be created in Windows OS on the computer with the installed MS SQL Server. | SQL Server server from Intellect the Axxon PSIM distributive and Intellect Axxon PSIM are installed on different computers that are connected through the TCP/IP net network and are in the same net network domain. Meanwhile, the set username (login) and password are to must correspond to the username (login) and password used for to access to the SQL - server. | |
FullThe full-scale SQL Server server (supplementary additionally installed) and Intellect Axxon PSIM are installed on different computers, connected through the TCP/IP net network and are in within the same net network domain. Meanwhile, the user account for the user currently authorized in Windows OS on the computer , where Intellect Axxon PSIM is being installed is to must be created on the remote SQL Server.server | FullThe full-scale SQL Server server (supplementary additionally installed) and Intellect and Axxon PSIM are installed on the same or different computers that are connected through the TCP/IP net network and are in the same net network domain. Meanwhile, the set username (login) and password are to must correspond to the username (login) and password used for to access to the SQL - server. |
| Info | ||
|---|---|---|
| ||
| For the SQL Server server installed from Intellect the Axxon PSIM distributive, the “sa” "sa" username and “Intellect"PSIM_default_DB_4” " password are used by default. While installing When you install the Microsoft SQL Server Express 2014 2019 server database, you can change the password may be changed for to any other. |
Click the Next button.
| Info | ||
|---|---|---|
| ||
| If the system while being installed displays the “Rights If the Rights are required to create or edit databases” databases message , then appears during the system installation, you must stop the installation process must be stopped and then restarted restart again. |
The Advanced Settings advanced settings dialog box window is displayed.
Click the Next button.
The Ready ready to install dialog box window is displayed.
| Info | ||
|---|---|---|
| ||
| To change the setting, click the Back button. |
Click the Install button.
The Installing Intellect dialog box Then the dialog window of the Axxon PSIM installation process is displayed.
| Info | ||
|---|---|---|
| ||
Error of When you install Axxon PSIM on OS Windows 7 SP1 without the internet connection, the error during the driver installation for the FX4 card can occur while the Intellect software installation on the Windows 7 SP1 operating system without Internet connection. To eliminate this error, you must install the following missing Windows updates: |
Click the Finish button.
| Info | ||
|---|---|---|
| ||
Then After that, the Axxon Driver Pack will be installed. add-on installation starts. If the KB2999226 update is installed, but there is no software ability to identify it, run the Axxon Driver Pack installation from the command prompt with the SOFT_INSTALL = "yes" parameter. |
...
...
| title | Note |
|---|
...
Installing the Axxon PSIM software with the server installation type is completeThe Intellect as a Server is now installed.