Go to documentation repository
...
| Note | ||
|---|---|---|
| ||
Buttons are active only when you interact with the selected event. If you click in any other place, they become inactive. |
Events The Current events tab displays events registered by alarm objects with no type assigned and security system objects that aren't assigned any type, and the events escalated from a lower level are displayed in the Current events tab. The event control panel is at the top of the tab, and the information on events is at the bottom of the tab.
The details of the event display:
| Info | ||
|---|---|---|
| ||
Event cells can display not only video screenshots but also images received from devices connected to the camera. For this, the operator protocol must receive an event with the imageBase64 parameter, containing a base64-encoded image that must be displayed. Such events can be generated, for example, using a script. |
...
On the right, there is a checklist of actions that must be performed during the event processing. This list is set up by the administrator during the operator protocol configuration. After you perform the required action, set the checkbox next to it, and the information about the task completion will be are added to the comment field along with the date and time indication.
...
To assign a type to the event, select one or several event cells or lines using with the left mouse button (hold down the Ctrl key to select several events if this feature is enabled in the system settings) and then click one of the buttons on the event control panel. The buttons for event processing can be unavailable until a comment is entered if the corresponding setting is enabled. If the help guides files were specified during the system configuration, the operator can click the button and open the help guide about with the description of the event processing.
| Info | ||
|---|---|---|
| ||
If the events are grouped , then selecting and you select a line with the grouping name will select name of the group, all events from in this groupinggroup are selected. The The presence of the event processing buttons depends on the settings of the operator protocol. |
The You can change the button names can be changed during the system configuration stage.
...
| Info | ||
|---|---|---|
| ||
When you select the an event cell or line, the camera linked to the corresponding object activation event an event of camera activation is generated. If If the Active monitor is configured in the system (see Configuring the display mode of camera windows), then video from the corresponding camera is displayed in it. If you select several cells are selected, then cameras are displayed one-by-one on the active monitor. |
After the type is assigned to the event, it is removed from the Current events tab in the operator protocol window. If you don't set the event, after being processed, isn't removed removal of the event from other operator protocols when configuring the operator protocol (see Administrator's Guide, the after being processed (see Setting the options for handling events in the Operator protocol section), then the processed event is marked grey in other operator protocol windows. But other operators can process this event once again.
...
In order to delay the event processing once for the time period specified when configuring the operator protocol, click the Delay button. The event will not be isn't removed from the operator protocol windows, and it will not be isn't marked grey in other operator protocols.
| Info | ||
|---|---|---|
| ||
If event processing must be confirmed by a password, that is, the Password for closing checkbox is set (see Setting the options for handling events in the Operator protocol) or the Yes value is selected in the Request password column (see Setting up the event filter for the Operator protocol) in the settings of the operator protocol, you must enter login and password as in the user authorization settings (see Assigning rights and password to operators for authorization in Axxon PSIM). If the waiting time of waiting for the response from the operator specified in the settings of the the Operator protocol object (see Administrator's Guide) is exceeded, then the event is escalated, and if the chief admin interface isn't assigned to the operator protocol, then it is removed from the Current events tab and the Non-processed type is assigned. When When you restart Axxon PSIM is restarted, the non-processed events are saved. |
...
...
...
If you want to create a bookmark for the selected event in the archive, set the Set the bookmark checkbox before processing the event. The comment will be is used as the bookmark name. See List of bookmarks.
If the events are displayed as cells, then you can zoom in on the frame of the moment of alarm (screenshot of the event) can be enlarged. To do this, double-click itthe frame. The window with the zoomzoomed-in frame appears. This window can be moved opens. You can move this window around the screen by dragging the title bar with the left mouse button; in this case, the position of the window will be is saved for each type of event and the operator protocol window. To close this window, click the X button in the upper right corner or press Esc on the keyboard.
| Info | ||
|---|---|---|
| ||
Enlarging the A zoomed-in frame of the alarm moment can be unavailable if the corresponding value of the hide_image_preview registry key is set (see Registry keys reference guide). |
A frame on the Current events tab is blurred until the end of the archive fragment recording to which this frame belongs.
If the If the Equipment detection (PPE) object is created and configured for the camera, borders outlines around detected objects can appear on the frame. The border outline color and thickness are determined set by the RectColor and RectLineWidth registry keys (see Registry keys reference guide).
...
To view or export the video of the event, select the event in the list and click the Enter archive button on the control panel. The enter the archive feature is available for events from the Camera objects and objects linked to them cameras (see Administrator's Guide, the Connection of objects with cameras section).
If you select the ActiveX video display method was selected during the system configurationsystem configuration, the window for the video viewing and exporting will openopens. The ActiveX window interface is the same as the Video video surveillance monitor interface.
When you open ActiveX by an alarm object, the ActiveX windows of all cameras linked with this object are opened.
You can move this window This window can be moved around the screen by dragging the title bar with the left mouse button; in this case, the position of the window will be is saved for each type of event and window of the operator protocol. To close this window, click the X button in the upper right corner or press Esc on the keyboard.
If you select the monitor was selected, then the required camera(s) will be displayed on the selected monitor in the archive viewing mode. In this case, the current playback position will be is set to the position corresponding to the beginning of the video recording. The ArchShift registry key can shift the current playback position (see Registry keys reference guide).
To view the object from which the event comes on the interactive map, click the event in the list and then click the Find on map button on the event control panel. As a result, the required layer of the interactive map is displayed. The corresponding object is highlighted outlined with green dots and marked with concentric black-and-white circles.
...