Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Multichannel digital-to-analogue conversion 4/4 and 16/4 Sensor-Relay cards can be installed on the Server depending on the security system requirements:

The 4/4 Sensor-Relay cards enable to process the signals from 4 sensors and the 16/4 cards - from 16 sensors. Simultaneously with processing the sensors signals these cards perform digital-analogue convesion and transmit up to 4 control signals to executive devices (relays).

The 4/4 and 16/4 Sensor-Relay cards have power (24V) and grounding terminals and are installed on FS-5, FS-6, FS-16 and FS-8 video capture cards.  

Connect Sensor-Relay cards as follows:  

  1. Make sure that power supply of the video capture card is off.
  2. Install the Sensor-Relay card on the video capture card with the help of special connectors.

    Connector on the Sensor-Relay card for connecting to the video capture card (by the example of 4/4 and 16/4 Sensor-Relay cards):

    Connector on the video capture card for connecting the Sensor-Relay card (by the example of FS6 video capture card):

    Installation of the Sensor-Relay card on the video capture card (by the example of 4/4 and 16/4 Sensor-Relay cards and FS6 video capture card):

  3. Fix the Sensor-Relay card on the video capture card with the help of screws bundled with the distribution kit of the Sensor-Relay card.
  4. Connect the interface cable (bundled with the distribution kit of the Sensor-Relay card) to the Sensor-Relay card with the help of special connector:

    Note

    For interface cable connection the 4/4 Sensor-Relay card has J6 connector, 16/4 Sensor-Relay card has J6 and J7 connectors.

    Attention!

    The first wire of the interface cable (marked red) is to match the first pin of corresponding connector of the Sensor-Relay card.

    Sensor-Relay interface cable:
    :
    Connectors on the Sensor-Relay card for the interface cable connection (by the example of 4/4 and 16/4 Sensor-Relay cards):

    J6 and J7 connector pinout:

    Example of the interface cable connection to the 4/4 Sensor-Relay card:

  5. To connect Sensor-Relay, unsolder the connector bundled with the distribution kit of the Sensor-Relay card. Unsoldering is made in accordance with the external connector pinout of the Sensor-Relay interface cable, taking into account power circuit of connected devices.
    External connector pinout of the Sensor-Relay interface cable:

    Sensor types and features of their connection:

    Example of power relay connection (with external power supply):

    Example of low-power relay (power supply on the card):



  6. Fix the unsoldered connector in the casing bundled with the distribution kit of the Sensor-Relay card.
  7. Connect ready-for-use connector to external connector of the Sensor-Relay interface cable in order to connect Sensor-Relay to the Server.

The Sensor-Relay cards are now connected.

  • No labels