The data about events registered in the system is stored in the Protocol table in Axxon PSIM (by default) or in the Protocol table of an individual database (see Extracting event protocol into an individual database).
The Event Viewer database is configured by means of the settings panel of the Computer system object.
Configure the Event Viewer database as follows:
In the Events archive length field specify the time period for storing the event archive in the Event Viewer database (3). This setting is relevant only for the Server corresponding to the Computer object. To specify the time period for storing the event archive for all Servers in the distributed system, use the common settings in the Programming tab (see The Settings panel of the Security zone object section). The value of the Events archive length parameter on the settings panel of the Computer object has the higher priority.
Note
If no value is specified in the Events archive length field on the configuration panel of the Computer object, the value specified in the configuration panel of the Security zone object is used.
Note
The Event Viewer database is now configured.