You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Current »

Configuration of Satel2 ETHM-A integration module is performed by configuring two system objects: Satel Ethma TCP Service object and Satel Ethma child object.

On the page:

Configuring Satel Ethma TCP Service object

To configure the Satel Ethma TCP Service object, do the following:

  1. Select the main Satel Ethma TCP service object.
  2. In the Polling time [s] field, enter the value specified when configuring the Satel2 ETHM-A universal monitoring module via GX Soft tool.
  3. In the VMS IP address, specify server IP address used to connect Axxon One with the Satel2 ETHM-A universal monitoring module.
  4. In the VMS Port, specify the port used to connect Axxon One with the Satel2 ETHM-A universal monitoring module.

    Attention!

    Make sure the firewall is configured to allow traffic from the Satel2 ETHM-A universal monitoring module to Axxon One server.


    Note

    The values need to be kept consistent with the ones specified when configuring the Satel2 ETHM-A universal monitoring module via GX Soft tool (see Preparing the Satel2 ETHM-A universal monitoring module to work with Axxon One).

  5. Click the Apply button to save the settings. 
  6. Click the  button, and from the drop-down list select Download configuration from device.

  7. Click the Apply button.

As a result, Satel Ethma object will be created.

Configuring Satel Ethma child object

To configure Satel2 Ethma object, do the following:

  1. In the Device IP field, enter the Satel2 ETHM-A universal monitoring module IP address.
  2. In the Input AC number field, specify the amount of AC inputs configured in Satel2 ETHM-A universal monitoring module.
  3. In the Number of 1-Wire sensors field, specify the amount of sensors configured in Satel2 ETHM-A universal monitoring module.

    Note

    In order to determine the amount of inputs and outputs to be selected, refer to the Input/Output preview section on the page Preparing the Satel2 ETHM-A universal monitoring module to work with Axxon One

  4. In the Number of inputs field, specify the amount of inputs configured in Satel2 ETHM-A universal monitoring module.
  5. In the Number of outputs field, specify the amount of outputs configured in Satel2 ETHM-A universal monitoring module. 
  6. Click the Apply button to save the settings.
  7. Go to the Satel Ethma TCP Service object.
  8. Click the  button, and from the drop-down list select Download configuration from device.
  9. Click the Apply button.

As a result, the available inputs, outputs and sensors will be added to the Satel Ethma object device tree.

  • No labels