To work with the Emulator integration module, you must install and configure the AxACFA feature. For more details, see Connecting and configuring the AxACFA feature.

To configure the parent object of the Emulator module, do the following:

  1. Create the Emulator parent object on the basis of the Axacfa object on the Hardware tab of the System settings dialog window.

  2. Go to the settings panel of the Emulator object.

  3. The Address field automatically contains the local IP address of the computer that you can change if necessary. In future versions, it will be possible to specify the IP address of the computer for remote connection and control of the emulator.

  4. In the Auth token field, specify a token for logging into Swagger softwarea framework that allows you to automatically describe APIs based on its code.
  5. In the ACS units field, specify the number of ACS (Access Control System) objects you want to create. The default value is 20. One object consists of one lock and two readers (child objects). You cannot change the number of child readers of one lock.

  6. In the FSA units field, specify the number of FSA (Fire and Security Alarm) of the Sensor object. The default value is 20.
  7. In the Fence units field, specify the number of PID (Perimeter Intrusion Detection System) of the Fence object. The default value is 20.
  8. In the Download delay, s field, specify the interval in seconds between the creation of two objects. The default value is 0. We don’t recommend changing it.
  9. In the Server port field, specify the port number via which Swagger software will be available.

  10. From the Server is active drop-down list, select Enabled to activate Swagger software. By default, Swagger is disabled (the Disabled value is selected).
  11. From the Enable swagger UI drop-down list, select Enabled to activate Swagger software in the browser. By default, Swagger is disabled in the browser (the Disabled value is selected).
  12. Click the Apply button to save the settings.
  13. Click the Download configuration button to automatically build the hardware tree according to the configuration specified in the previous steps: